LRC-1100 Column speaker, 100cm, EN54
EV_LRC_Family_Black+White
LRC Series

LRC-1100

One-meter passive column with switchable 20°/40° vertical coverage and integrated 70/100 V power — as installed in Shakespeare's church.
Loading

LRC-1100 Column speaker, 100cm, EN54

A passive line-radiator install column with a built-in 70/100-V transformer and ASC protection.

The LRC Series — Line Radiator Column — is built for installations where audio quality and clean architecture carry equal weight. Purpose-built 2.5-inch drivers sit behind proprietary PaSS phase plugs that control vertical dispersion, so energy lands on listeners instead of exciting reflective floors, ceilings, and walls. The paintable enclosure comes in RAL 9004 signal black or RAL 9003 signal white and mounts close to the wall on the SwifTilt bracket, which conceals cables and hardware.

The LRC-1100 doubles the driver count: twelve 2.5-inch drivers plus passive radiators in a 950 mm column reaching 65 Hz. Vertical coverage switches between 20° and 40°, with a 5° acoustic down-tilt built into the pattern, and the integrated 70/100 V transformer (taps to 120 W) carries patented Automatic Saturation Compensation. At Holy Trinity Church — Shakespeare's church — LRC-1100 columns keep energy off centuries-old stone in the chancel and choir stalls.

What the LRC-1100 brings

PaSS dispersion control
Twelve 2.5-inch drivers and passive radiators reach 65 Hz while holding a controlled vertical pattern.
Switchable coverage
20° or 40° vertical patterns with a 5° acoustic down-tilt aim the sound without visibly tilting the column.
SwifTilt mounting
Flush, pan, and tilt from one compact bracket: ±80° pan at every down-tilt angle, tilt to 25°, inverted mounting, concealed cables.
All-weather, certified
IP56c weatherized for full outdoor exposure, EN54 certified, paintable RAL black or white.
70/100 V + ASC
Integrated transformer with taps from 120 W down to 8 W; patented ASC guards electronics while keeping low-frequency response.
System-matched DSP
Dedicated presets for Dynacord DSP matrix processors and amplifiers, with EASE, PREVIEW, and SONICUE software support.
2026-DC-EV-HolyTrinityChurch_03
Case study

Heard in Shakespeare's church

Holy Trinity Church in Stratford-upon-Avon — where Shakespeare is buried — replaced an end-of-life 100 V system with an Electro-Voice and Dynacord solution. LRC-1100 columns in the chancel and choir stalls control vertical dispersion naturally, keeping energy off centuries-old stone while speech lands clearly in every pew.

Specifications at a glance

  • Frequency range (−10 dB): 65 Hz – 14 kHz

  • Max SPL: 126 dB narrow / 123 dB wide · sensitivity 93/91 dB (1 W/1 m)

  • Coverage: 130° × 20° or 40° switchable, 5° acoustic down-tilt

  • Power handling: 200 W continuous / 400 W program (8 Ω)

  • Transformer taps: 120/60/30/15/8 W @ 70 V · 120/60/30/15 W @ 100 V

  • Connections: 4-pin Euroblock, input + pass-through (12 AWG max)

  • 950 × 110 × 150 mm · 7.6 kg · IP56c · EN54

All figures from the LRC-1100 engineering data sheet.

Explore the Full Column Speakers Range

All three LRC columns — 60 cm, 100 cm, and the two-way 1 m — compared side by side on the Column Speakers page.

Features

Mount it once and forget it. The LRC-1100 is a passive line-radiator column engineered for install, with a pre-fitted transformer for 70- or 100-volt lines. EV's patented Automatic Saturation Compensation preserves low-frequency response and protects the electronics from improper loads, regardless of how many speakers hang on the line. The included bracket aims flush, tilted, inverted, or panned to match the wall. Mains, support, foreground, or background — one tidy column covers the part.
  • Drops onto distributed lines — pre-installed transformer for 70- or 100-volt systems.
  • Protects the system — patented ASC preserves low end and guards electronics against improper loads.
  • Aims almost any way — included bracket handles flush, downtilt, up-tilt (inverted), and pan.
  • Blends in — sleek, neutral industrial column that suits mains, support, foreground, or background.
  • Best with Dynacord — dedicated presets on Dynacord DSP matrix processors and amplifiers tune output and protection.

Specifications

Overview & Features

Configuration

Twelve 2.5" active drivers with PaSS phase plugs; three 2.5" and six 6.5" passive radiators

Acoustic Performance

Max SPL

126

Frequency Response

-2 4

Frequency Range (-10 dB)

65

Coverage angle (H)

130

Coverage angle (V)

40